NCL SW-PU V Single-Component Flexible Injection Resin
PRODUCT DESCRIPTION
COMPOSITION
AREA OF APPLICATION
FEATURES & ADVANTAGES
MATERIAL DATA
REACTION DATA
*The reaction time at 25 °C varies with the amount of water added. Result may vary depending on site condition.
APPLICATION GUIDELINE
PACKAGING
STORAGE & HANDLING
HEALTH & SAFETY
OTHER INFORMATION
NCL SW-PU V is a ready-to-use hydrophobic hydroactive single-component flexible Polyurethane injection resin specially designed for permanent sealing of water leakages on vibratory structure. It is suitable for sealing all type of leaking concrete defects especially live cracks, movement joints and other imperfection that caused water ingress.
NCL SW-PU V is fast reacting to water. It is moisture sensitive and reacts rapidly in contact with water to foams a permanent flexible watertight seal. Due to its resilient flexibility, it allows and absorbs movement from concrete structure e.g. parking area, tunnel, track bed, under-construction building etc.
Once cured, NCL SW-PU V remain permanently flexible and forms an excellent water-impermeable barrier against moisture and water infiltration.
NCL SW-PU V is fast reacting to water. It is moisture sensitive and reacts rapidly in contact with water to foams a permanent flexible watertight seal. Due to its resilient flexibility, it allows and absorbs movement from concrete structure e.g. parking area, tunnel, track bed, under-construction building etc.
Once cured, NCL SW-PU V remain permanently flexible and forms an excellent water-impermeable barrier against moisture and water infiltration.
COMPOSITION
NCL SW-PU V is a single component Polyurethane Injection Resin based on methylene diphenol isocyanate and polyether polyol. It is ready-to-use, no mixing is required.
AREA OF APPLICATION
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FEATURES & ADVANTAGES
|
|
|
|
|
|
|
|
MATERIAL DATA
UNIT | PART A | |
Appearance | - | Yellowish |
Viscosity | mPa.s | 500-600 |
Specific Gravity (at 25 °C) | - | 1.08 |
Flash Point | °C | >200 |
REACTION DATA
Resin:Water Ratio | Cream Time (second) | Rise time (second) |
1:1 | 2 | 50 |
2:1 | 2 | 50 |
3:1 | 3 | 60 |
4:1 | 4 | 70 |
5:1 | 8 | 75 |
6:1 | 10 | 80 |
7:1 | 13 | 90 |
8:1 | 15 | 105 |
9:1 | 20 | 120 |
10:1 | 25 | 135 |
APPLICATION GUIDELINE
NCL SW-PU V can be injected using single-line high-pressure injection machine e.g. NCL SWM1000, NCL SWM1100, NCL DHP-M1000 or NCL DHP-M2000. The injection resin is ready-to-use, no mixing is required. Refer to Method Statement for complete guide.
FINAL PRODUCT
The single component hydrophobic injection resin reacts, expands and foams to dense permanent flexible watertight seal in contact with moisture or water.
PACKAGING
Contents | Weight | |
Single Component NCL SW-PU V | 10 kg |
STORAGE & HANDLING
It is recommended to keep container tightly closed in a cool (20 - 25°C), dry and well-ventilated place. Partly used drums/pails should be properly sealed to prevent ingress of moisture. To increase the material life expectancy, partially used drum/pail can be filled with nitrogen gas and sealed tightly to prevent contamination. When the material is stored properly, the shelf life is approximately twelve (12) months from the production date.
WASTE DISPOSAL
Waste disposal should be in accordance with all applicable local and national regulations. Kindly check with the local authorities on proper disposal method. Empty drums/pails should be punctured to clear the content. Care must be taken to prevent environmental contamination from the use of this material.
HEALTH & SAFETY
- Ingestion: Do not induce vomiting. Treat symptomatically and get medical attention immediately.
- Inhalation: Remove from exposure. If there is any difficulty in breathing, get medical attention immediately.
- Skin Contact: Remove contaminated clothing. Immediately flush affected area thoroughly with mild soap and water.
- Eye Contact: Immediately flood eyes with plenty of water for a minimum of 15 minutes holding the eyes open.
OTHER INFORMATION
All information contain herein was obtained from sources which we believe to be accurate and reliable. The information is subject to change without prior notice. However, it is provided without any warranty, expressed or implied, regarding its correctness. The information is provided for informational purposes and solely for customer’s consideration, investigation and verification. The statements in this information sheet are based on the best of our knowledge and experience. For this and other reasons, NCL Chemical & Equipment Sdn Bhd do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the material. However, we have no control over the method of application and the amount of care taken when using this product and therefore the liability of NCL Chemical & Equipment Sdn Bhd is limited to the quality of the delivered material.